Document
  • Product
    01.

    Battery Management Systems

    Low Voltage

    FS-LT CT-Safe CT-Lite CT-Lite + 50A CT-Lite + 80A

    High Voltage

    FS-XT HP Safe
    02.

    Other Advanced Electronics

    Power Management

    SB-PR-I

    Telematics

    IoT
    03.

    Upcoming Projects

  • Applications

    2-Wheelers

    2W- Bike, Moped, Kick Scooter, and E-Cycle

    3-wheelers

    3W- E-Auto

    4-Wheelers

    4W- Electric Car, Golf Cart

    Outdoor Powered Equipment

    Outdoor powered equip- Lawn Mower, Construction Machinery

    Unmanned Aircraft System

    Unmanned Aircraft System- Logistics & delivery drones, Agriculture & Mapping UAVs

    Industrial Application

    Industrial Application- Forklifts, Excavators, Mining equipment, Robots

    Energy Storage

    Energy storage- BESS

    AGV

    AGV- Cleaning machines, Warehouse robots

    Commercial Vehicles

    CV- Bus, Truck, Car, Golf cart

  • Company
    01.

    About Us

    02.

    Careers

    Latest Blog

    Maxwell’s Path to BMS Reliability: A Comprehensive Journey

  • Insights
    01.

    Blogs

    02.

    Case Studies

    Latest Blog

    Maxwell’s Path to BMS Reliability: A Comprehensive Journey

  • Ecosystem
Get in touch
Document
  • Product
    01.

    Battery Management Systems

    Low Voltage

    FS-LT CT-Safe CT-Lite CT-Lite + 50A CT-Lite + 80A

    High Voltage

    FS-XT HP Safe
    02.

    Other Advanced Electronics

    Power Management

    SB-PR-I

    Telematics

    IoT
    03.

    Upcoming Projects

  • Applications

    2-Wheelers

    2W- Bike, Moped, Kick Scooter, and E-Cycle

    3-wheelers

    3W- E-Auto

    4-Wheelers

    4W- Electric Car, Golf Cart

    Outdoor Powered Equipment

    Outdoor powered equip- Lawn Mower, Construction Machinery

    Unmanned Aircraft System

    Unmanned Aircraft System- Logistics & delivery drones, Agriculture & Mapping UAVs

    Industrial Application

    Industrial Application- Forklifts, Excavators, Mining equipment, Robots

    Energy Storage

    Energy storage- BESS

    AGV

    AGV- Cleaning machines, Warehouse robots

    Commercial Vehicles

    CV- Bus, Truck, Car, Golf cart

  • Company
    01.

    About Us

    02.

    Careers

    Latest Blog

    Maxwell’s Path to BMS Reliability: A Comprehensive Journey

  • Insights
    01.

    Blogs

    02.

    Case Studies

    Latest Blog

    Maxwell’s Path to BMS Reliability: A Comprehensive Journey

  • Ecosystem
Get in touch
Client Support
1-800-356-8933
Get in touch
  • Products
    • CT-Lite
    • CT-Lite+
    • CT-Lite+ 80A
    • CT-Safe
    • FS-LT
    • FS-XT
    • HP-Safe
    • SB-PR-I
    • TCU
  • Applications
    • 2-wheelers
    • 3-Wheelers
    • 4-Wheelers
    • Automated Guided Vehicles
    • Energy Storage Systems
    • Industrial Applications
    • Outdoor Powered Equipment
    • Passenger and Commercial Vehicles
    • Unmanned Aircraft System
  • Company
    • About
    • Careers
  • Resources
    • Case studies
  • Eco System
  • Products
    • CT-Lite
    • CT-Lite+
    • CT-Lite+ 80A
    • CT-Safe
    • FS-LT
    • FS-XT
    • HP-Safe
    • SB-PR-I
    • TCU
  • Applications
    • 2-wheelers
    • 3-Wheelers
    • 4-Wheelers
    • Automated Guided Vehicles
    • Energy Storage Systems
    • Industrial Applications
    • Outdoor Powered Equipment
    • Passenger and Commercial Vehicles
    • Unmanned Aircraft System
  • Company
    • About
    • Careers
  • Resources
    • Case studies
  • Eco System
BMS Battery

Cell Balancing Explained: Active vs Passive Balancing for Lithium-Ion Battery Packs

cell balancing

Quick Read

Cell balancing is how a BMS keeps every cell in a battery pack at the same charge. Without it, the weakest cell limits the whole pack, reducing usable capacity and shortening battery life. Passive balancing burns off excess charge from fuller cells as heat, while active balancing moves it to weaker cells at 80 to 95% efficiency. Both help the pack charge fully, last longer and stay safer, with active balancing best suited to high-cycle, large-format packs

A lithium-ion battery pack is only as strong as its weakest cell. That single fact is the reason cell balancing exists  and the reason getting it right determines whether a battery pack delivers its rated capacity across thousands of cycles or quietly loses usable energy from the very first hundred.

This guide covers everything: what cell balancing is, how passive and active balancing work at the circuit level, which method fits which application, and how to choose a BMS with the right balancing architecture for your battery pack. If you’re new to battery management, start with our article, What is BMS? A Complete Guide to Battery Management Systems.

What Is Cell Balancing?

Cell balancing is the process by which a Battery Management System equalises the State of Charge across all cells in a series-connected battery pack. The goal is to ensure every cell reaches the same voltage at full charge and discharges to the same voltage at cutoff  so the full capacity of every cell in the pack is accessible during every cycle. Since balancing is all about State of Charge, it helps to understand the metric itself. Read our article on, What Are SOH and SOC in a Battery? How Are They Measured and Key Differences? 

In a perfectly balanced pack, all cells charge and discharge together, hitting their voltage limits at the same moment. In the real world, no pack stays perfectly balanced  and the BMS’s cell balancing function is what corrects the drift continuously.

Why Do Cells in a Battery Pack Become Unbalanced?

Cell imbalance begins before the battery ever cycles. Even in a carefully matched pack, cells leave the factory with minor differences in capacity, internal resistance, and self-discharge rate. These differences are small, often within 1–2% at the start of life. But they compound.

Over hundreds of cycles, minor capacity differences mean some cells fully charge before others. Minor resistance differences mean some cells generate more heat than others, accelerating their degradation relative to cooler cells. Minor self-discharge differences mean cells that sit at rest lose charge at different rates. Temperature gradients within the pack  cells closer to the cooling system running cooler than cells at the pack centre  accelerate divergence further.

The result: a pack that begins life with tightly matched cells develops growing voltage spread over time. Without active correction from the BMS, this spreads compounds with every cycle.

The Weakest-Cell Problem

The weakest cell in the pack determines the pack’s operational limits in both directions. On charge, the BMS must stop charging when the highest-voltage cell reaches its maximum limit  even if every other cell still has headroom. On discharge, the BMS must be cut off when the lowest-voltage cell hits its minimum limit  even if every other cell still has energy to deliver.

The practical consequence: a pack with 5% cell voltage spread at end of charge cannot access 100% of its rated capacity. The energy sitting above the weakest cell’s cutoff in every other cell is stranded. As imbalance grows over cycle life, the gap between rated capacity and accessible capacity grows with it, manifesting as range loss in EVs and reduced runtime in stationary storage systems. For a closer look at how this capacity loss shows up over years of driving, read our article on Electric Car Battery Life: How Long They Last and How to Maximize Battery Health. 

Why Is Cell Balancing Important?

More Usable Capacity and Runtime

A balanced pack accesses its full rated capacity on every cycle. An unbalanced pack loses access to a growing fraction of that capacity as the voltage spread between cells widens. For a 100-cell series string with 10% voltage spread, the capacity penalty is significant; the pack effectively behaves as if it has fewer cells. For a fleet operator or BESS project owner, this capacity loss is directly measurable as reduced vehicle range or reduced energy delivery from the storage asset.

Longer Battery Life

Imbalanced cells experience unequal stress. Cells that consistently reach full charge voltage before their neighbours are repeatedly exposed to high-SOC conditions, the part of the voltage range where lithium-ion aging is most aggressive. Cells that consistently hit the discharge cutoff first are repeatedly exposed to deep discharge stress. Both conditions accelerate degradation in the affected cells, creating a self-reinforcing cycle where the weakest cells age fastest, increasing imbalance, increasing stress on those cells, and accelerating their degradation further.

Cell balancing interrupts this cycle. By keeping all cells at equivalent SOC throughout charge and discharge, balancing distributes aging stress evenly across the full pack, extending the cycle life of the weakest cells and slowing the overall pack degradation rate.

Better Safety

Cell imbalance is a thermal risk as well as a capacity risk. Cells that repeatedly overcharge  because the BMS is still charging the pack to equalise other cells when this cell is already full  experience lithium plating, electrolyte oxidation, and heat generation. In severe cases, a chronically overcharged cell is a thermal runaway initiation point. Cell balancing prevents this by ensuring no cell is consistently driven above its maximum voltage during normal pack operation.

How Does Cell Balancing Work in a BMS?

Three consequences make cell balancing critical to every lithium-ion application capacity, longevity, and safety.

What the BMS Monitors

The BMS measures individual cell voltage across every cell in the pack continuously  using Analog Front End (AFE) ICs that sample all cells in a module simultaneously with measurement accuracy typically better than ±1 mV. This real-time, cell-level voltage data is the input to all balancing decisions.

The BMS also monitors cell temperature  which affects the relationship between voltage and SOC  and pack current, which affects voltage readings during active charge and discharge (a cell under load shows a lower terminal voltage than its true open-circuit voltage). Accurate balancing requires the BMS to account for these factors, which is why cell balancing in a quality BMS involves more than a simple voltage comparison. Voltage sensing is just one of the jobs a BMS handles. Read our article on What Is BMS in an Electric Vehicle? Functions, Benefits & Importance for the full picture. 

When Balancing Starts

Most BMS implementations trigger balancing when the cell voltage spread exceeds a defined threshold  typically 10–30 mV for passive balancing, potentially tighter for active balancing in precision applications. Balancing is most effective near the top of the charge curve, where the voltage-SOC relationship is steepest and small voltage differences represent meaningful SOC differences. Many BMS designs activate balancing only during the constant-voltage (CV) phase of charging, when the pack is near full and the charger is tapering current, minimizing the interference between balancing currents and charge current measurement.

Top Balancing vs Bottom Balancing

Top balancing equalises cells at the top of the charge curve  at or near full charge. This is the standard approach for lithium-ion packs in EV and ESS applications. It ensures the full pack can charge to 100% together and that no cell is overcharged during the end-of-charge phase. Top balancing is the correct approach for applications where maximum range and full capacity utilisation are the priority.

Bottom balancing equalises cells at the bottom of the discharge curve  near empty. It ensures all cells hit their minimum voltage cutoff together during full discharge. This approach was historically used in some applications where full discharge is the primary use case but is less common in modern lithium-ion BMS designs, where protecting cells from deep discharge is a key BMS function.

Passive Cell Balancing

Before any balancing decision is made, the BMS needs accurate, real-time data from every cell. Here is what it measures and why each measurement matters.

How Passive Cell Balancing Works

Passive balancing reduces the voltage of higher-charged cells by bleeding excess energy through a resistor  converting the energy difference between cells into heat rather than transferring it to lower-charged cells. The BMS identifies cells with voltage above the target threshold and switches a resistor across each of those cells, allowing current to flow through the resistor until the cell’s voltage drops to match the lowest cell in the pack.

The energy dissipated is lost permanently; it does not benefit any other cell. The net effect is that the whole pack is brought down to the level of the weakest cell rather than the weaker cells being brought up to the level of the stronger ones.

Fixed vs Switched Shunt Resistors

Fixed shunt resistors are permanently connected across each cell. Simple and reliable but continuously dissipate energy even when balancing is not needed, unacceptable for most practical applications due to standby power losses.

Switched shunt resistors connect the resistor across a cell only when the BMS activates a MOSFET switch for that cell’s balancing circuit. This is the standard passive balancing implementation; the BMS controls which cells are being balanced at any moment, activating and deactivating switches based on real-time voltage data. Balancing current in passive designs is typically 50–200 mA, sized to provide adequate balancing speed without excessive heat generation in the resistors.

Advantages and Limitations of Passive Balancing

Passive balancing is the simpler of the two approaches both in circuit design and in the underlying principle. Understanding how it works makes its tradeoffs immediately clear.

Advantages:

  • Simple circuit design with fewer components
  • Lower cost  resistors and MOSFETs are inexpensive and well-understood
  • Reliable and easy to implement in firmware
  • Sufficient for applications with moderate cycle counts and small cell voltage spread
  • Low component count means fewer potential failure modes

Limitations:

  • Energy is wasted as heat  balancing efficiency is 0% (energy removed from one cell benefits no other cell)
  • Heat generation requires thermal management consideration  particularly in large packs where simultaneous balancing of many cells generates meaningful heat
  • Balancing speed is limited by resistor power rating  too much current generates too much heat
  • Not suitable for high-cycle applications where the cumulative energy waste and capacity loss from imperfect equalisation become significant over thousands of cycles

Active Cell Balancing

Active balancing solves the core problem passive balancing cannot instead of discarding the energy difference between cells, it puts that energy to use.

How Active Cell Balancing Works

Active balancing transfers charge from higher-voltage cells to lower-voltage cells using energy conversion circuits, DC-DC converters, switched capacitors, or transformer-based topologies. Unlike passive balancing, the energy is not wasted, it is moved. The higher-charged cell delivers energy to the conversion circuit, which transfers it to the lower-charged cell, equalising voltages without dissipating the energy difference as heat.

Active balancing is bidirectional  energy that can flow from any cell to any other cell, or from the full pack to a weak cell, or from a strong cell to the full pack. This flexibility allows more sophisticated balancing strategies than passive designs permit.

Types of Active Balancing Circuits

Capacitor-Based (Switched Capacitor)

Switched capacitor balancing uses a flying capacitor that alternately connects to adjacent cells  charging from the higher-voltage cell and discharging into the lower-voltage cell. Simple implementation, no magnetic components, and zero transformer or inductor design complexity. The limitation: energy transfer occurs only between adjacent cells, meaning large voltage differences across many cells require many switching cycles to equalise  slow convergence for large series strings.

Inductor-Based (Buck-Boost)

Inductor-based active balancing uses a buck-boost converter to transfer energy between cells at controlled current levels. The inductor stores energy from the source cell during one switching phase and releases it to the target cell during the next. Buck-boost topologies allow cell-to-cell transfer across any two cells in the string, not just adjacent pairs enabling faster convergence for large packs. Higher component count and more complex control algorithm than switched capacitor, but meaningfully better balancing speed for large series strings.

Transformer-Based (Flyback)

Flyback converters use transformer isolation to transfer energy between cells with galvanic isolation between the source and destination. The transformer’s turns ratio can be configured to match the voltage levels of the source and target efficiently. Flyback topologies are particularly suited to pack-to-cell or cell-to-pack transfer of energy from the full pack bus to a weak cell, or from a strong cell to the full pack bus  enabling fast balancing of outlier cells without requiring energy to pass through multiple intermediate cells. Higher cost and complexity, but the preferred topology for high-performance BMS designs in large-format ESS and premium EV applications.

Advantages and Limitations of Active Balancing

Advantages:

  • Energy is transferred, not wasted  balancing efficiency of 80–95% depending on topology
  • Higher balancing current is achievable without the heat generation constraint of passive designs
  • Faster convergence  large voltage differences can be corrected more quickly
  • Better long-term capacity retention  the pack’s usable capacity stays closer to its rated value across more cycles
  • More sophisticated balancing strategies are possible  pack-to-cell, cell-to-pack, and cell-to-cell transfer modes

Limitations:

  • More complex circuit design  more components, more potential failure modes
  • Higher cost  DC-DC converters, inductors, and transformers add bill of materials cost
  • More complex BMS firmware to manage bidirectional energy transfer and topology-specific control
  • Efficiency is not 100%  5–20% of transferred energy is lost in the conversion circuit, though this is still far better than passive balancing’s 0% efficiency

What Is an Active Balancing BMS?

An active balancing BMS is a Battery Management System that integrates active cell balancing circuitry with the converter topologies described above  alongside its standard cell monitoring, protection, and state estimation functions. The BMS firmware manages the balancing algorithm: determining which cells need balancing, which direction energy should flow, and which converter circuits to activate.

A BMS with active balancing costs more than a passive-only design  but for applications with high cycle counts, large cell counts, or strict capacity retention requirements, the additional cost is recovered through extended battery life and maintained capacity across the operational life of the pack. This is also why most battery pack builders now discuss balancing architecture with their BMS manufacturer in India or abroad at the design stage, rather than treating it as an add-on later. 

Active vs Passive Cell Balancing: Key Differences

Beyond the two primary methods sits a third approach that attempts to take the best of both.

FeaturePassive BalancingActive Balancing
Energy handlingDissipated as heatTransferred to weaker cells
Efficiency0% (energy lost)80–95%
Balancing current50–200 mA typical0.5–5A+ depending on topology
CostLowHigher
Circuit complexitySimpleComplex
Heat generationSignificant at high currentMinimal
Best applicationLow-to-moderate cycle countHigh-cycle, large packs, ESS
Convergence speedSlowerFaster
Long-term capacity retentionModerateHigh

What Is Hybrid Cell Balancing?

Hybrid cell balancing combines passive and active balancing in a single BMS design  using passive balancing for fine-grain top-of-charge equalisation (where small current, simple implementation suffices) and active balancing for large imbalances or during discharge (where energy transfer efficiency matters). Hybrid designs attempt to capture the cost simplicity of passive balancing for routine maintenance while having active capability available for correction of larger imbalances that passive balancing cannot address efficiently. Found in some mid-tier BMS designs as a cost optimization between full passive and full active architectures.

Cell Balancing in Lithium-Ion Batteries: NMC vs LiFePO4

Chemistry determines how balancing behaves in practice. The same BMS balancing algorithm produces different results on NMC and LFP cells for reasons rooted in how their voltage curves are shaped.

NMC and NCA Cells (18650, 21700)

NMC and NCA cells have a voltage range of approximately 3.0V (discharged) to 4.2V (fully charged) with a sloped discharge curve across most of the SOC range. This sloped curve is beneficial for cell balancing; voltage differences between cells translate relatively directly to SOC differences across most of the operating range, making voltage-based balancing triggers accurate and reliable.

NMC cells are more thermally sensitive than LFP, and the consequence of chronically overcharging a weak NMC cell is a more severe  elevated thermal risk rather than just capacity loss. This makes accurate, consistent balancing more critical for NMC packs than for LFP. Active balancing is more commonly specified in high-performance NMC applications for this reason.

LiFePO4 (LFP) Batteries

LFP cells have a much flatter discharge voltage curve; voltage is nearly constant across 20–80% SOC, varying by only 50–100 mV across a wide SOC range. This flatness creates a specific challenge for cell balancing: a 20 mV voltage difference between two LFP cells near 50% SOC may correspond to a 30%+ SOC difference rather than the 5% difference the same 20 mV spread would indicate in an NMC cell.

The practical implication: LFP cell balancing must be performed near the extremes of the voltage curve  where the voltage-SOC relationship steepens enough to make voltage-based balancing meaningful  rather than in the flat mid-range where voltage is an unreliable SOC indicator. Top balancing at the end of the constant-voltage charge phase is the standard approach for LFP packs. Coulomb counting-based balancing triggers, rather than pure voltage-based triggers, improve accuracy for LFP applications.

How to Check If Your Battery Cells Are Unbalanced

Not all voltage spread is a problem. The first step is knowing what normal looks like.

Normal Voltage Difference Between Cells

In a healthy, balanced lithium-ion pack at rest (no current flowing), cell voltage spread should be within 10–20 mV for NMC and 5–10 mV for LFP. Spread above 50 mV indicates meaningful imbalance that is affecting usable capacity. Spread above 100 mV is significant and warrants active correction or investigation of underlying cell health.

During active charge or discharge, voltage spread is larger due to resistance differences between cells; this is normal and does not indicate balancing problems. Balancing assessments should be made at rest, after a sufficient relaxation period for terminal voltages to settle toward open-circuit values.

Signs of an Unbalanced Battery Pack

Reduced range or runtime: The pack cuts off at the minimum voltage threshold earlier than expected, the weakest cell hitting its limit while other cells still have charge remaining.

Charging stops before full capacity: The pack terminates charge earlier than expected, the highest-voltage cell hitting its maximum before the rest of the pack is fully charged.

BMS protection trips during normal operation: Overvoltage or undervoltage protection activating at conditions where the full pack SOC appears normal is a symptom of severe individual cell voltage outliers.

Increasing range variability: Day-to-day range variation without changes in driving pattern or temperature is a sign of growing cell voltage spread affecting accessible capacity inconsistently.

BMS diagnostic data: Any BMS with cell-level telemetry will show the voltage spread directly. A spread greater than 50 mV at rest is the clearest diagnostic signal.

How to Fix an Unbalanced Pack

For minor imbalance within normal aging, the BMS’s balancing function corrects the drift automatically over several charge cycles with no intervention required. For significant imbalance that has developed due to degraded cells, extended storage, or BMS failure, options include:

Allow the BMS to balance over multiple full cycles  leaving the pack on charge for extended periods to allow passive balancing to work through the spread gradually.

Manual cell-level balancing  for accessible pack formats, connecting individual cells to a cell balancer or controlled charger to bring voltage into range before reassembling the pack.

Module replacement  for severe imbalance caused by a degraded or failed cell or module, replacing the affected module brings the pack back into balance. Requires a BMS with module-level SOH data to identify the specific module causing the spread.

Passive or Active: Which Cell Balancing Method Do You Need?

The right balancing method is not always the most sophisticated one. The decision comes down to three variables: cycle rate, pack size, and how much capacity retention matters over the battery’s full life.

When Passive Balancing Is Enough

Passive balancing is the right choice when cycle count is moderate (under 500–1,000 cycles per year), cell voltage spread is small and stable, cost is a primary constraint, and the application does not require maximum capacity retention across many years of operation. Consumer electronics, entry-level two-wheelers, and small backup power systems typically fall into this category. The energy waste from passive balancing is acceptable when the absolute pack capacity is small and the operational lifetime is modest.

When You Need a BMS with Active Balancing

Active balancing is the right choice for high-cycle applications  commercial EV fleets, grid-scale BESS, electric buses  where the cumulative effect of balancing efficiency over thousands of cycles is significant. It is also appropriate for large series strings (many cells in series) where passive balancing convergence is too slow to keep pace with the imbalance introduced by each cycle, and for premium applications where maximum capacity retention across the full battery life justifies the additional cost. If grid storage is your use case, read our article on What Is a Battery Energy Storage System (BESS)? to see why cycle life drives project economics. 

How Much Balancing Current Do You Need?

Balancing current determines how quickly the BMS can correct cell voltage spread. For passive balancing, 50–200 mA is typically sufficient for maintaining balance in a well-matched pack but slow for correcting large imbalances. For active balancing, 0.5–5A+ is achievable depending on topology, enabling faster convergence.

The required balancing current scales with three factors: the size of the imbalance to be corrected (larger spread requires more current to correct in a reasonable time), the number of charge-discharge cycles per day (higher cycle rate creates faster imbalance accumulation that balancing must keep pace with), and the acceptable correction timeframe (balancing during the CV charge phase only, versus balancing continuously including during discharge).

For most commercial EV and ESS applications, active balancing at 1–3A provides the right balance of correction speed, circuit complexity, and cost.

Conclusion: Choosing the Right Cell Balancing Method

Cell balancing is not a peripheral BMS feature; it is the function that determines whether a battery pack delivers its rated capacity across its full design life or progressively loses usable energy as cells drift apart.

Passive balancing is simple, cost-effective, and adequate for many applications. Active balancing is more expensive and more complex, but it is the only approach that maintains efficiency and capacity retention across high-cycle, large-format applications where battery performance is a direct revenue and operational driver.

The right choice depends on chemistry, application, cycle rate, and the total cost of ownership equation over the battery’s operational life. For applications where the battery is a significant capital asset grid-scale BESS, commercial EV fleets, premium passenger vehicles  the cost of active balancing is consistently justified by the capacity and cycle life it preserves.

Maxwell Energy’s BMS solutions support both passive and active balancing architectures across LFP, NMC, and NCA chemistries with configurable balancing thresholds, currents, and trigger conditions that can be tuned precisely to the application’s requirements.

What does cell balancing mean?

Cell balancing equalises the State of Charge across all cells in a series-connected battery pack so every cell charges and discharges together. It ensures the full capacity of every cell contributes to the pack’s usable energy on every cycle.

FAQ

1. How does BMS do cell balancing?

 The BMS monitors individual cell voltage continuously. When spread between cells exceeds a threshold, it activates either resistors across higher-voltage cells (passive) or DC-DC converters that transfer charge between cells (active) until all cells return to within the target voltage window.

2. How to balance a cell?

Within a pack, the BMS handles it automatically. For individual cells outside a pack, a controlled charger or dedicated cell balancer brings the voltage to match the target. Severely degraded cells are better replaced than balanced.

3. Why is the cell balance procedure performed?

To prevent the weakest cell from limiting the full pack’s capacity, distribute aging stress evenly across all cells, extend cycle life, and eliminate the thermal risk of chronically overcharged or over-discharged cells.

4. How does active cell balancing work?

Active balancing uses energy conversion circuits, switched capacitors, buck-boost converters, or flyback transformers to transfer charge from higher-voltage cells to lower-voltage ones. Energy is moved, not wasted, achieving efficiencies of 80–95%.

5. Which is better, active or passive balancing?

Active is better for high-cycle, large-format applications where capacity retention and efficiency matter over thousands of cycles. Passive is better where cost is the primary constraint and cycle count is moderate. The right answer depends on the application.

6. Which is better, a BMS or an active balancer?

A BMS with integrated active balancing. It manages protection, state estimation, communication, and balancing within one system  with balancing decisions directly informed by real-time cell data rather than external estimation.

7. What is the purpose of cell balancing?

To maximise usable pack capacity, extend cycle life, maintain consistent performance, and prevent safety risks from cells drifting outside their safe operating window over time.

8. What are the three types of BMS?

A centralized single board manages all cells. Modular standardised modules handle fixed cell groups under a master controller. Distributed satellite boards handle cell-level measurement with a master for system-level logic.

9. Will two batteries in parallel equalise?

Yes, parallel-connected batteries naturally equalise toward the same terminal voltage through circulating current. For large voltage differences, this current can stress cells, which is why BMS inter-circulating current prevention is important in parallel-connected systems.

10. What are the different types of cell balancing techniques?

Passive balancing (resistive dissipation), active balancing (capacitor-based, inductor-based, transformer-based), and hybrid balancing (combining both). Within active balancing, topologies include switched capacitor, buck-boost, and flyback  each with different efficiency, speed, and cost trade-offs.

“” “”

Related articles

Uncategorized

MOSFET vs Contactor Based BMS: What’s the difference?

In the electrifying world of Battery Management Systems (BMS), choosing between MOSFETs (Metal-Oxide-Semiconductor Field-Effect Transistors) and contactors can make or break your battery system’s performance. Buckle up as we dive into this comprehensive technical comparison

The latest insights, straight to your inbox

Registered Office

S. No. 218, Solitaire Office No. 5, Kalyani Nagar, Yerwada,Pune – 411 006, Maharashtra, India

Head Office, India

No. 24, 2nd Floor, Kalyani Platina Phase I, EPIP Zone Phase I, Whitefield, Bengaluru 560 066

Manufacturing Facility

Sarang Society, Near Gajanan Maharaj Mandir, Garkheda Road, Plot No. 41, CTS No. 15308/32, Chhatrapati Sambhajinagar, Maharashtra 431 009

image 56
image 55
Group 190072
Vector

Products

  • CT-Lite
  • CT-Lite+ 80A
  • CT-Safe
  • FS-LT
  • CT-Lite+
  • CT-Lite
  • CT-Lite+ 80A
  • CT-Safe
  • FS-LT
  • CT-Lite+
  • FS-XT
  • HP-Safe
  • SB-PR-I
  • IoT
  • FS-XT
  • HP-Safe
  • SB-PR-I
  • IoT

Company

  • Investor Relations
  • About us
  • Careers
  • Investor Relations
  • About us
  • Careers

Resources

  • Blog
  • Case studies
  • Upcoming projects
  • Blog
  • Case studies
  • Upcoming projects

Join us

  • Open Positions
  • Open Positions
We are hiring
2026 - Maxwell Inc. All Rights Reserved.
Linkedin
Linkedin

Make in India

top

Inactive

Simplifying IT
for a complex world.
  • About us
  • Why us
  • Team
  • Partners & Certifications
  • Reviews & Awards
  • About us
  • Why us
  • Team
  • Partners & Certifications
  • Reviews & Awards
Platform partnerships
  • AWS
  • Google Cloud
  • Microsoft
  • Salesforce

Inactive

Services
  • Managed Services
  • IT Consulting & Advisory
  • Cyber Security
  • Web Development
  • Mobile Development
  • Cloud Services
  • Managed Services
  • IT Consulting & Advisory
  • Cyber Security
  • Web Development
  • Mobile Development
  • Cloud Services
Business Challenges

Digital Transformation

Security

Automation

Gaining Efficiency

Industry Focus
  • Industry Manufacturing
  • Transportation Logistics
  • Healthcare
  • Banks & Insurance
  • Consulting Providers
  • Non Profit
  • Industry Manufacturing
  • Transportation Logistics
  • Healthcare
  • Banks & Insurance
  • Consulting Providers
  • Non Profit
View all